GLF-314 SF6 Gas Infrared Imaging Leak Detector
● Intuitive display of gas leak status in real time.
● Gas-enhanced infrared mode to detect very small gas leaks.
● Embedded operating system, UI design similar to mobile phone and tablet makes it easy for users to get started.
● USB, WiFi, HDMI multiple data transmission methods.
● High-resolution rotatable LCD display.
● High-resolution viewfinder with adjustable angle for bright light.
● Lightweight, robust design.
● Anti-fatigue ergonomic design.
● Thermal imager host
● Power adapter
● Lithium-Ion rechargeable batteries and chargers
● USB cable
● HDMI video cable
● 32G TF memory card and card reader
● User manual
● Packing box
|
N0. |
Items | Specifications | |
|
1 |
Detector and optical parameters |
Detector type |
Uncooled infrared detectors |
|
2 |
Infrared resolution |
384×288 |
|
|
3 |
Pixel spacing |
25μm |
|
|
4 |
Filter bandpass response wavelength |
7μm–8.5μm、9.5μm -12μm |
|
|
5 |
Thermal sensitivity (NETD) |
<0.1℃@30℃ |
|
|
6 |
Detectable gas |
7μm–8.5μm:CH4 9.5μm -12μm: SF6 |
|
|
7 |
Infrared lens |
Standard lens(21.7°±2°)× (16.4°±2°) |
|
|
8 |
Infrared focus |
Manual & auto |
|
|
9 |
Image display |
Digital zoom |
1 to 10 times continuous digital zoom |
|
10 |
Image frame rate |
50Hz±1Hz |
|
|
11 |
Display resolution |
1024×600 |
|
|
12 |
Display screen |
5-inch touch screen, resolution 1024×600 |
|
|
13 |
Viewfinder |
OLED high-resolution display, 1024 x 600 pixels |
|
|
14 |
Display mode |
Infrared mode. Gas boost mode. Infrared temperature measurement mode. Visible light mode. Picture-in-picture mode. Fusion mode; |
|
|
15 |
Image adjustment |
Automatic and manual brightness and contrast adjustment |
|
|
16 |
Palette |
10 types + 1 user-defined |
|
|
17 |
Digital camera |
The field of view is consistent with the infrared lens |
|
|
18 |
LED lights |
Yes |
|
|
19 |
Temperature measurement and analysis |
Temperature measurement range |
1 gear: -20 — 150°C 2 gear: 100 — 650°C |
|
20 |
Accuracy |
±3℃or ±3%(Take the larger value, the ambient temperature is 15°C to 35°C) |
|
|
21 |
Center point temperature measurement |
Yes |
|
|
22 |
Movable point temperature measurement |
Supports 10 points |
|
|
23 |
Movable area temperature measurement |
Supports 10 circles and 10 rectangles |
|
|
24 |
Movable line temperature measurement |
Supports 10 lines |
|
|
25 |
High and low temperature point positioning |
Support full-screen high and low temperature point positioning and high and low temperature point positioning in the area |
|
|
26 |
Measurement presets |
No measurement, center point, maximum temperature point, minimum temperature point, average temperature |
|
|
27 |
Temperature alarm |
Color alarms (isothermal lines): above/below specified temperature levels, between specified temperature levels. Measurement function alarms: Audible alarms (above/below/between specified temperature levels). |
|
|
28 |
Measured value correction |
Emissivity (0.01 to 1.0 selectable), reflected temperature, relative humidity, atmospheric temperature, target distance, external ir window compensation |
|
|
29 |
Date storage |
Storage medium |
Removable TF memory card |
|
30 |
Take pictures regularly |
3 seconds to 24 hours |
|
|
31 |
Native full radiometric image analysis |
Saved radiometric thermal images can be edited and analyzed on the camera |
|
|
32 |
Image file format |
Standard JPEG images, including digital photographs and full radiometric data |
|
|
33 |
Radiometric infrared video recording |
Real-time radiation video recording, *.raw file is stored in TF card |
|
|
34 |
Non-radiative infrared video recording |
*.avi video file, save to TF card |
|
|
35 |
Image annotation |
Voice: 60 seconds, stored with image Text: Add table, choose between predefined templates |
|
|
36 |
Remote display view |
View video streams in real-time over a Wi-Fi connection. Connect to display via HDMI high-definition interface; |
|
|
37 |
Remote operation control |
Connect to dedicated software control via Wi-Fi; |
|
|
38 |
Communication and peripherals |
interface |
USB 2.0, Wi-Fi, HDMI |
|
39 |
WIFI |
Yes |
|
|
40 |
Audio |
Microphone and speaker for image voice annotation and video recording |
|
|
41 |
laser pointer |
Yes |
|
|
42 |
GPS |
Support satellite positioning, location information can be saved in the image |
|
|
43 |
Power supply |
Battery type |
Rechargeable lithium electronic battery |
|
44 |
Battery voltage |
7.4v |
|
|
45 |
Continuous working time |
Not less than 4 hours at room temperature |
|
|
46 |
External power supply |
Support external dc12v power supply |
|
|
47 |
Power management |
Automatic shutdown or automatic screen off, the time can be selected from never, 5min, 10min, 30min |
|
|
48 |
Environmental adaptability
|
Operating temperature |
-20 - +50℃ |
|
49 |
Storage temperature |
-40 - +70℃ |
|
|
55 |
Physical properties |
Weight (without battery) |
≤ 1.8 kg |
|
56 |
Dimensions (H*W*L) |
≤185 mm × 148 mm × 155 mm (including standard lens) |
|
|
57 |
Tripod mount base |
Standard, 1/4"-20 |
|
● Intuitive display of gas leak status in real time.
● Gas-enhanced infrared mode to detect very small gas leaks.
● Embedded operating system, UI design similar to mobile phone and tablet makes it easy for users to get started.
● USB, WiFi, HDMI multiple data transmission methods.
● High-resolution rotatable LCD display.
● High-resolution viewfinder with adjustable angle for bright light.
● Lightweight, robust design.
● Anti-fatigue ergonomic design.
●Thermal imager host
●Power adapter
●Lithium-Ion rechargeable batteries and chargers
●USB cable
●HDMI video cable
●32G TF memory card and card reader
●User manual
●Packing box
|
N0. |
Items | Specifications | |
|
1 |
Detector and optical parameters |
Detector type |
Uncooled infrared detectors |
|
2 |
Infrared resolution |
384×288 |
|
|
3 |
Pixel spacing |
25μm |
|
|
4 |
Filter bandpass response wavelength |
7μm–8.5μm、9.5μm -12μm |
|
|
5 |
Thermal sensitivity (NETD) |
<0.1℃@30℃ |
|
|
6 |
Detectable gas |
7μm–8.5μm:CH4 9.5μm -12μm: SF6 |
|
|
7 |
Infrared lens |
Standard lens(21.7°±2°)× (16.4°±2°) |
|
|
8 |
Infrared focus |
Manual & auto |
|
|
9 |
Image display |
Digital zoom |
1 to 10 times continuous digital zoom |
|
10 |
Image frame rate |
50Hz±1Hz |
|
|
11 |
Display resolution |
1024×600 |
|
|
12 |
Display screen |
5-inch touch screen, resolution 1024×600 |
|
|
13 |
Viewfinder |
OLED high-resolution display, 1024 x 600 pixels |
|
|
14 |
Display mode |
Infrared mode. Gas boost mode. Infrared temperature measurement mode. Visible light mode. Picture-in-picture mode. Fusion mode; |
|
|
15 |
Image adjustment |
Automatic and manual brightness and contrast adjustment |
|
|
16 |
Palette |
10 types + 1 user-defined |
|
|
17 |
Digital camera |
The field of view is consistent with the infrared lens |
|
|
18 |
LED lights |
Yes |
|
|
19 |
Temperature measurement and analysis |
Temperature measurement range |
1 gear: -20 — 150°C 2 gear: 100 — 650°C |
|
20 |
Accuracy |
±3℃or ±3%(Take the larger value, the ambient temperature is 15°C to 35°C) |
|
|
21 |
Center point temperature measurement |
Yes |
|
|
22 |
Movable point temperature measurement |
Supports 10 points |
|
|
23 |
Movable area temperature measurement |
Supports 10 circles and 10 rectangles |
|
|
24 |
Movable line temperature measurement |
Supports 10 lines |
|
|
25 |
High and low temperature point positioning |
Support full-screen high and low temperature point positioning and high and low temperature point positioning in the area |
|
|
26 |
Measurement presets |
No measurement, center point, maximum temperature point, minimum temperature point, average temperature |
|
|
27 |
Temperature alarm |
Color alarms (isothermal lines): above/below specified temperature levels, between specified temperature levels. Measurement function alarms: Audible alarms (above/below/between specified temperature levels). |
|
|
28 |
Measured value correction |
Emissivity (0.01 to 1.0 selectable), reflected temperature, relative humidity, atmospheric temperature, target distance, external ir window compensation |
|
|
29 |
Date storage |
Storage medium |
Removable TF memory card |
|
30 |
Take pictures regularly |
3 seconds to 24 hours |
|
|
31 |
Native full radiometric image analysis |
Saved radiometric thermal images can be edited and analyzed on the camera |
|
|
32 |
Image file format |
Standard JPEG images, including digital photographs and full radiometric data |
|
|
33 |
Radiometric infrared video recording |
Real-time radiation video recording, *.raw file is stored in TF card |
|
|
34 |
Non-radiative infrared video recording |
*.avi video file, save to TF card |
|
|
35 |
Image annotation |
Voice: 60 seconds, stored with image Text: Add table, choose between predefined templates |
|
|
36 |
Remote display view |
View video streams in real-time over a Wi-Fi connection. Connect to display via HDMI high-definition interface; |
|
|
37 |
Remote operation control |
Connect to dedicated software control via Wi-Fi; |
|
|
38 |
Communication and peripherals |
interface |
USB 2.0, Wi-Fi, HDMI |
|
39 |
WIFI |
Yes |
|
|
40 |
Audio |
Microphone and speaker for image voice annotation and video recording |
|
|
41 |
laser pointer |
Yes |
|
|
42 |
GPS |
Support satellite positioning, location information can be saved in the image |
|
|
43 |
Power supply |
Battery type |
Rechargeable lithium electronic battery |
|
44 |
Battery voltage |
7.4v |
|
|
45 |
Continuous working time |
Not less than 4 hours at room temperature |
|
|
46 |
External power supply |
Support external dc12v power supply |
|
|
47 |
Power management |
Automatic shutdown or automatic screen off, the time can be selected from never, 5min, 10min, 30min |
|
|
48 |
Environmental adaptability
|
Operating temperature |
-20 - +50℃ |
|
49 |
Storage temperature |
-40 - +70℃ |
|
|
55 |
Physical properties |
Weight (without battery) |
≤ 1.8 kg |
|
56 |
Dimensions (H*W*L) |
≤185 mm × 148 mm × 155 mm (including standard lens) |
|
|
57 |
Tripod mount base |
Standard, 1/4"-20 |
|