Recently, a testing service company in Hebei purchased a batch of high-voltage test equipment from our company. This equipment includes: GDJS-A series of intelligent insulating gloves (boots) test set, GDYD-D series of digital display hipot test set, GDJ series Insulating rod test electrode device, GDY series electroscope function test device, GDDT-30D grounding group resistance tester and other equipment. So far, this batch of equipment has been shipped successfully.

GDJS-A series of intelligent insulating gloves (boots) withstand voltage test set is an advanced intelligent voltage test equipment platform designed according to the latest national power industry standards. This platform host computer and our company’s GDMA-2 intelligent high-voltage milliammeter wireless network, combined with various auxiliary electrode test structures, constitute an intelligent insulating glove (shoe) withstand voltage test device, which can accurately measure multiple high-voltage leakage currents. This device can test 6 or 8 samples at the same time. In order to avoid repeated tests, the unique high-voltage breaking technology is adopted. The punctured test product continues to test until the test is completed. On the one hand, the high-voltage trip protects the test product, on the other hand, it also protects the step-up transformer, and reduces the impact of the ignition of the test product on other measurements nearby, which greatly improves the test work. efficient. It can be used for the safety protection equipment necessary for the operation and maintenance of power systems such as insulating boots and insulating gloves to assess the insulation level of the product, find the insulation defect of the test product, and measure the ability of overvoltage.

Intelligent insulating gloves (boots) withstand voltage test device scope of application:
is widely used in the mass production inspection and testing of insulating gloves and insulating boots in electrical manufacturing departments, power operation departments, scientific research units and universities.
HV Hipot has specialized in the production of high-voltage test equipment for more than 20 years. Now it has developed into a company with a group of specialized R&D and production teams and professional after-sales technical teams. It is capable of customizing electrical test products with different configurations in response to test requirements of different voltage levels. , Welcome new and old customers to drop orders enthusiastically!
Post time: Oct-21-2021